No Milk

Profi and Z5

1. Remove frother. Check steam. If there is no steam or weak steam see  "Steam Arm- No Steam or Water" in troubleshooting.

2. If there is good steam the frother is blocked. Clean the frother.

3. If it has been already cleaned something is still blocking it. Strip and soak overnight in milk steam cleaner and warm water.

4. Replace frother.

 

X7

Is there steam?

No-Blocked or calcified. Needs to come into workshop.

Yes- Blockage in milk system. Strip and clean milk system. If it has been already cleaned something is still blocking it.

Strip and soak milk system and hose overnight in milk steamer cleaner and warm water.

 

X9

Is there steam?

No- Blocked or calcified. Needs to come into workshop.

Yes- Blockage in milk system. Strip and clean milk system. If it has been already cleaned something is still blocking it.

Strip and soak outlet nozzle assembly and hoses overnight in milk steam cleaner and warm water.

Most common blockage points-white tube, black elbows taht have red o-ring on them.

Make sure it is assembled correctly. Hot milk from left nozzle, white tube and milk outlet.

Frothed milk from right nozzle, black tube and milk outlet.